Furon® HPVM Valve - 2 Way Manual Multi-Turn

High Purity Compact Valve

Furon HPVM 2 Way Manual Multi-Turn Valves from Saint-Gobain are designed to minimize the entrapment of liquids and engineered to handle the most aggressive chemistries and abrasive slurries. Featuring a compact footprint with a common port height among all configurations, HPVM Valves are easy to install in tight spaces.

Specifications

Item # CAD Actuation End Connection size in (mm) End Connection Type Orifice in (mm) Panel Mount Max. Back Discharge Pressure Psig (bar) Flow Factor Cv Liquid Type
HPVM2-S300-46-MT
  • Multi-Turn
  • Manual
3/8 (9.525)
  • Nippon Pillar Super 300®
1/4" (6.35) Yes 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry
HPVM2-S300-44-MT
  • Multi-Turn
  • Manual
1/4 (6.35)
  • Nippon Pillar Super 300®
1/4" (6.35) Yes 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry
HPVM2-F46-MT
  • Multi-Turn
  • Manual
3/8 (9.525)
  • Flare
1/4" (6.35) Yes 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry
HPVM2-F44-MT
  • Multi-Turn
  • Manual
1/4 (6.35)
  • Nippon Pillar Super 300®
1/4" (6.35) Yes 80 (5.5) 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry
HPVM2-F34-MT
  • Multi-Turn
  • Manual
  • Flare
3/16" (4.7625) Yes 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry
HPVM2-744-MT
  • Multi-Turn
  • Manual
  • FuseBond™
1/4" (6.35) Yes 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry
HPV2-144-MT
  • Multi-Turn
  • Manual
  • FNPT
1/4" (6.35) Yes 0.7
  • High Purity Water
  • High Purity Chemistry
  • Slurry

Technical

Max. Liquid Temperature °F (°C) 203 (95)
Max. Inlet Liquid Pressure Psig (Bar) 80 (5.5)
Max. Outlet Liquid Pressure Psig (Bar) 80 (5)
Max. Liquid Back Pressure Psig (Bar) 80 (5.5)
Flow Path 2 Way
Leak Detection Port Yes
Nut Material PFA
Visual Indicator Yes

Applications

Applications
  • Wafer Processing Solutions

Features & Benefits

  • Pressure rated up to 80 PSIG (5.5 bar)
  • Optimum Cv 0.70
  • Tested for more than 1 million cycles
  • Compatible integration into our custom manifold solution
  • Molded body to ensure premium surface finish and material quality
  • High cycling duty in Slurry & Chemical applications

Related Documents

Download Selected (0)
Furon HPVM Valve - 2 Way Manual Multi-Turn Datasheet
Datasheet
Furon HPVM Valve - 2 Way Manual Multi-Turn Datasheet
High-Purity Fluid Handling Solutions for Microelectronics
Brochure
High-Purity Fluid Handling Solutions for Microelectronics
Case Study: Furon HPV Valve - High Temperature
Case Study
Case Study: Furon HPV Valve - High Temperature
Statement of Performance: Furon® HPVM - Reliability in 37% HCl
Statement of Performance
Statement of Performance: Furon® HPVM - Reliability in 37% HCl
Statement of Performance: Furon® HPVM Accelerated Life Testing in Slurry
Statement of Performance
Statement of Performance: Furon® HPVM Accelerated Life Testing in Slurry