Furon® A2 Pumps

High Purity Bellow Pump
Furon A2 Pumps from Saint-Gobain feature a 100% PFA and PTFE wetted flow path which contain no metal parts or elastomeric seals, assuring compatibility with even the most aggressive chemicals. These high-purity pumps have pumping rates ranging from 4 GPM to 16 GPM. For abrasive slurries, special configurations are available to assure reliability in the most demanding pumping conditions. Slurry pumps feature specially designed bellows to prevent particle agglomeration and premature failure.
Features & Benefits
- No metal parts
- 100% high purity PFA and PTFE wetted flow path
- 100% elastomer free
- Worldwide service center for preventive maintenance
- Unique recirculating pilot air concept to improve system uptime
- Stall-proof twin shuttle option available
- Low pulsation level with the use of Furon A2 Dampener technology
- Furon A2 Pumps have been tested for more than 130 million cycles
- ATEX compliant
Specifications
Item # | End Connection size in (mm) | Liquid Type | Driving System Logic | Max. Flow Rate GPM (LPM) | Max. Back Discharge Pressure Psig (bar) | Max Suction Head ft (m) | Max. Air Consumption scfm (m3/h) | Weight lbs (kg) | Pump Size | CAD |
---|---|---|---|---|---|---|---|---|---|---|
A2CH1 T8 | 1/2 (12.7) |
|
Plug and Play | 4 (15) | 80 (5.5) | 10 (3) | 4.5 (7) | 5 (2.26) | 1 | |
A2CH1 T8 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 4 (15) | 80 (5.5) | 10 (3) | 4.5 (7) | 5 (2.26) | 1 | |
A2CH1 T8 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 4 (15) | 80 (5.5) | 10 (3) | 4.5 (7) | 5 (2.26) | 1 | |
A2CH2 T12 | 1/2 (12.7) |
|
Plug and Play | 8 (30) | 80 (5.5) | 12 (3.5) | 6 (9) | 9 (4.08) | 2 | |
A2CH2 T12 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 8 (30) | 80 (5.5) | 12 (3.5) | 6 (9) | 9 (4.08) | 2 | |
A2CH2 T12 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 8 (30) | 80 (5.5) | 12 (3.5) | 6 (9) | 9 (4.08) | 2 | |
A2CH3 T16 | 1/2 (12.7) |
|
Plug and Play | 16 (60) | 80 (5.5) | 14 (4) | 9 (14) | 16 (7.25) | 3 | |
A2CH3 T16 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 16 (60) | 80 (5.5) | 14 (4) | 9 (14) | 16 (7.25) | 3 | |
A2CH3 T16 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 16 (60) | 80 (5.5) | 14 (4) | 9 (14) | 16 (7.25) | 3 | |
A2SY1 T8 | 1/2 (12.7) |
|
Plug and Play | 4 (15) | 80 (5.5) | 10 (3) | 4.5 (7) | 5 (2.26) | 1 | |
A2SY1 T8 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 4 (15) | 80 (5.5) | 10 (3) | 4.5 (7) | 5 (2.26) | 1 | |
A2SY1 T8 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 4 (15) | 80 (5.5) | 10 (3) | 4.5 (7) | 5 (2.26) | 1 | |
A2SY2 T12 | 1/2 (12.7) |
|
Plug and Play | 8 (30) | 80 (5.5) | 12 (3.5) | 6 (9) | 9 (4.08) | 2 | |
A2SY2 T12 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 8 (30) | 80 (5.5) | 12 (3.5) | 6 (9) | 9 (4.08) | 2 | |
A2SY2 T12 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 8 (30) | 80 (5.5) | 12 (3.5) | 6 (9) | 9 (4.08) | 2 | |
A2SY3 T16 | 1/2 (12.7) |
|
Plug and Play | 16 (60) | 80 (5.5) | 14 (4) | 9 (14) | 16 (7.25) | 3 | |
A2SY3 T16 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 16 (60) | 80 (5.5) | 14 (4) | 9 (14) | 16 (7.25) | 3 | |
A2SY3 T16 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 16 (60) | 80 (5.5) | 14 (4) | 9 (14) | 16 (7.25) | 3 | |
A2CH1 F8 | 1/2 (12.7) |
|
Plug and Play | 4 (15) | 85 (6) | 10 (3.048) | 4.5 (7) | 5 (2.26) | 1 | Download CAD |
A2CH1 F8 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 4 (15) | 85 (6) | 10 (3.048) | 4.5 (7) | 5 (2.26) | 1 | |
A2CH1 F8 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 4 (15) | 85 (6) | 10 (3.048) | 4.5 (7) | 5 (2.26) | 1 | |
A2CH2 F12 | 3/4 (19.05) |
|
Plug and Play | 8 (30) | 85 (6) | 12 (3.6576) | 6 (9) | 9 (4.08) | 2 | Download CAD |
A2CH2 F12 TWIN | 3/4 (19.05) |
|
Twin Shuttle | 8 (30) | 85 (6) | 12 (3.6576) | 6 (9) | 9 (4.08) | 2 | Download CAD |
A2CH2 F12 EXT | 3/4 (19.05) |
|
Programmable Logic Controller | 8 (30) | 85 (6) | 12 (3.6576) | 6 (9) | 9 (4.08) | 2 | Download CAD |
A2CH3 F16 | 1 (25.4) |
|
Plug and Play | (60) | 85 (6) | 14 (4.2672) | 9 (14) | 16 (7.25) | 3 | Download CAD |
A2CH3 F16 TWIN | 1 (25.4) |
|
Twin Shuttle | (60) | 85 (6) | 14 (4.2672) | 9 (14) | 16 (7.25) | 3 | Download CAD |
A2CH3 F16 EXT | 1 (25.4) |
|
Programmable Logic Controller | (60) | 85 (6) | 14 (4.2672) | 9 (14) | 16 (7.25) | 3 | Download CAD |
A2SY1 F8 | 1/2 (12.7) |
|
Plug and Play | 4 (15) | 85 (6) | 10 (3.048) | 4.5 (7) | 5 (2.26) | 1 | Download CAD |
A2SY1 F8 TWIN | 1/2 (12.7) |
|
Twin Shuttle | 4 (15) | 85 (6) | 10 (3.048) | 4.5 (7) | 5 (2.26) | 1 | |
A2SY1 F8 EXT | 1/2 (12.7) |
|
Programmable Logic Controller | 4 (15) | 85 (6) | 10 (3.048) | 4.5 (7) | 5 (2.26) | 1 | |
A2SY2 F12 | 3/4 (19.05) |
|
Plug and Play | 8 (30) | 85 (6) | 12 (3.6576) | 6 (9) | 9 (4.08) | 2 | Download CAD |
A2SY2 F12 TWIN | 3/4 (19.05) |
|
Twin Shuttle | 8 (30) | 85 (6) | 12 (3.6576) | 6 (9) | 9 (4.08) | 2 | |
A2SY2 F12 EXT | 3/4 (19.05) |
|
Programmable Logic Controller | 8 (30) | 85 (6) | 12 (3.6576) | 6 (9) | 9 (4.08) | 2 | |
A2SY3 F16 | 1 (25.4) |
|
Plug and Play | 16 (60) | 85 (6) | 14 (4.2672) | 9 (14) | 16 (7.25) | 3 | Download CAD |
A2SY3 F16 TWIN | 1 (25.4) |
|
Twin Shuttle | 16 (60) | 85 (6) | 14 (4.2672) | 9 (14) | 16 (7.25) | 3 | |
A2SY3 F16 EXT | 1 (25.4) |
|
Programmable Logic Controller | 16 (60) | 85 (6) | 14 (4.2672) | 9 (14) | 16 (7.25) | 3 |
Technical
Max. Liquid Temperature °F (°C) | 212 (100) |
Max. Liquid Back Pressure Psig (Bar) | 80 (5.5) |
Max. Air Pressure Forward Psig (Bar) | 80 (5.5) |
Self Priming | Yes |
Viscosity | 500 |
Applications
Applications |
|
A2CH1 F8 - A2 Pump Operating Instructions

A2CH2 F12 - A2 Pump Operating Instructions

A2CH3 F16 - A2 Pump Operating Instructions

A2SY1 F8 - A2 Pump Operating Instructions

A2SY2 F12 - A2 Pump Operating Instructions


A2CH1 F8 TWIN - A2 Pump Operating Instructions

A2CH2 F12 TWIN - A2 Pump Operating Instructions

A2CH3 F16 TWIN - A2 Pump Operating Instructions

A2SY1 F8 TWIN - A2 Pump Operating Instructions

A2SY2 F12 TWIN - A2 Pump Operating Instructions

A2SY3 F16 TWIN - A2 Pump Operating Instructions

A2CH1 F8 EXT - A2 Pump External Drive Operating Instructions

A2CH2 F12 EXT - A2 Pump External Drive Operating Instructions

A2CH3 F16 EXT - A2 Pump External Drive Operating Instructions